- Configurations for testing to industry standards: IEC, SAE, BCI
- Test control and data management with Bitrode
- Up to three current ranges per circuit
- Temperature, pressure, flow rate, and cell voltage monitoring
- Digital inputs and digital outputs with function assigned per individual program
- Expression-based program limit conditions
- Internal resistance calculation
- Ramp charge/discharge
- Temperature compensation adjusts voltage per battery temperature
- Constant resistance discharge
- Remote Input Output (RIO) box reduces excessive cable lengths when connecting to remote test stations
- Custom-designed test leads
- Drive Cycle Conversion utility automates test program development from acquired battery usage data
- Reserve Capacity Testing: Perform a constant current discharge to see how long a useful voltage can be maintained on the battery
- Charge Acceptance Testing
General Specifications
Voltage: 5-18V
Current: 0-100A (1600A in parallel)
Circuits: up to 48
Network: Ethernet
Accuracy: ±0.1% of FS*
Data Sampling Rate: up to 10mS
Current: 0-100A (1600A in parallel)
Circuits: up to 48
Network: Ethernet
Accuracy: ±0.1% of FS*
Data Sampling Rate: up to 10mS
*Accuracy values are conservative assuming operation will be through the standard temperature range of 0-40° C and RH from 10-90% (non-condensing). Units calibrated and maintained in a temperature and humidity controlled environment can expect an accuracy of 0.02-0.05%FS.
Overview
The CV is Bitrode’s economical cycle life test equipment for the network based line of battery laboratory equipment. Designed to work with VisuaLCN Lab Client software, the CV provides standard or fully customized charge, discharge and rest cycles for automotive and industrial batteries. The Model CV is also useful for reserve capacity and charge acceptance testing with recharge.